Gmp panel factory 2024: Clean room equipment includes air purification equipment and air ventilation equipment. During the construction process, it is necessary to select the appropriate air filtration equipment according to specific practical needs. In general, the selection of air purification equipment will use coupled filtration technology to achieve the purpose of eliminating dust in the air, that is, through multiple layers of different filtration forms, to eliminate foreign particles and harmful substances in the air. Discover even more details on https://www.sz-pharma.com/gmp-clean-room-sandwich-panel.html.
Excellent tablet press dies manufacturer: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.
The clean room is generally made of foam color steel or rock wool board with a vertical wall and an independent air-conditioning air supply system. The air is filtered through high-efficiency three-stage filtration in junior high schools. The personnel and materials are equipped with an air shower room and a transfer window for clean filtration.
Suzhou Pharma is one of the leading turnkey project providers for pharmaceutical, food, herbal, cosmetic, electronics factory and chemical plants. We offer projects as per GMP regulations. As being pioneers in this field, the solutions from Suzhou Pharma is readily accepted by the customers. Our solid expertise in cleanroom allows meeting the precise needs of its customer’s industry in different sectors such as health,pharmaceutical, biotechnology, and cosmetics. We firmly believe in the principle of quality by design. Find more details at https://www.sz-pharma.com/.
Usually, the movement or activity of personnel should be reduced as much as possible in the laboratory, and the door of the clean room should be closed or automatic door closers should be installed to keep it closed. Stop use immediately when the cleanliness does not meet the requirements: When the cleanliness does not meet the requirements, it should be stopped immediately, find the cause, thoroughly clean, must be verified by the cleanliness and meet the requirements, and then use again, and record the situation in the aseptic room use register, regular archival storage. Guidance and supervision of incoming foreign personnel or maintenance personnel: non-microbial room inspection personnel shall not enter the clean room (aseptic room), and foreign personnel or maintenance personnel who must enter shall be guided and supervised.
Pharmaceutical equipment includes: granulating oven, boiling dryer, wet machine, pulverizer, vibrating screen, slicer, drug frying machine, drug frying machine, tablet press, pill making machine, multi-functional extraction tank, liquid storage tank, liquid distribution tank, decompression drying oven, tilting reaction pot, capsule filling machine, bubble type packaging machine, particle packaging machine, powder packaging machine, V-type mixer, lifting feeder, etc.
Efficiency of Equipment: Some equipment, such as electronics and mechanical components, require specific humidity levels to function correctly. Maintaining the right humidity levels in clean rooms ensures optimal performance and longevity of these critical pieces of equipment. How to Maintain Optimal Humidity Levels in Clean Rooms? To maintain optimal humidity levels in clean rooms, consider the following steps: Install a Dehumidifier: A dehumidifier is an essential tool for maintaining proper humidity levels in clean rooms. It removes excess moisture from the air, keeping humidity levels within the desired range. Choose a dehumidifier based on the size of your clean room and the relative humidity requirements you need to meet.
The clean room workshop is also called the dust free workshop, gmp cleanroom, the industrial clean room (Clean Room) and the dust free room. It refers to the removal of pollutants such as particles, harmful air and bacteria in the air within a certain space, and the indoor temperature,cleanliness, indoor pressure, air velocity and air distribution, noise and vibration, lighting and static control. A specially designed clean room for a particular requirement. That is to say, no matter how the extemal air conditions change, the clean room can maintain the characteristics of cleanliness temperature and humidity and pressure.
The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.